ChirpStack Decoder für Füllstandsmessung

Payload-Format (8 Bytes)

Das Gerät sendet 8 Bytes via LoRaWAN:

Bytes Beschreibung Einheit Berechnung
0-1 Distanz mm Big Endian uint16
2-3 Füllhöhe mm Big Endian uint16
4-5 Füllstand % × 10 Big Endian uint16 (855 = 85.5%)
6-7 Batterie mV Big Endian uint16 (3700 = 3.7V)

Decoder-Code für ChirpStack v4

function decodeUplink(input) {
  var bytes = input.bytes;
  var fPort = input.fPort;

  // Validierung
  if (bytes.length !== 8) {
    return {
      errors: ["Invalid payload length - expected 8 bytes, got " + bytes.length]
    };
  }

  if (fPort !== 1) {
    return {
      errors: ["Invalid fPort - expected 1, got " + fPort]
    };
  }

  // Distanz (Byte 0-1, Big Endian)
  var distanceMm = (bytes[0] << 8) | bytes[1];
  var distanceCm = distanceMm / 10.0;
  var distanceM = distanceMm / 1000.0;

  // Füllhöhe (Byte 2-3, Big Endian)
  var fillHeightMm = (bytes[2] << 8) | bytes[3];
  var fillHeightCm = fillHeightMm / 10.0;
  var fillHeightM = fillHeightMm / 1000.0;

  // Füllstand in % (Byte 4-5, Big Endian, × 10)
  var fillPercentRaw = (bytes[4] << 8) | bytes[5];
  var fillPercent = fillPercentRaw / 10.0;

  // Batteriespannung (Byte 6-7, Big Endian, in mV)
  var batteryMv = (bytes[6] << 8) | bytes[7];
  var batteryV = batteryMv / 1000.0;

  // Batterie-Prozent berechnen (LiPo: 3.0V = 0%, 4.2V = 100%)
  var batteryPercent = ((batteryV - 3.0) / (4.2 - 3.0)) * 100.0;
  if (batteryPercent < 0) batteryPercent = 0;
  if (batteryPercent > 100) batteryPercent = 100;

  return {
    data: {
      // Distanz (Sensor bis Flüssigkeit)
      distance_mm: distanceMm,
      distance_cm: distanceCm,
      distance_m: distanceM,

      // Füllhöhe (Flüssigkeitshöhe im Tank)
      fill_height_mm: fillHeightMm,
      fill_height_cm: fillHeightCm,
      fill_height_m: fillHeightM,

      // Füllstand in Prozent
      fill_percent: fillPercent,

      // Batterie
      battery_mv: batteryMv,
      battery_v: batteryV,
      battery_percent: Math.round(batteryPercent)
    }
  };
}

Beispiel-Payloads

Angenommen: Tank-Höhe = 180 cm

Payload (Hex) Distanz Füllhöhe Füllstand
0348 0AA0 0226 84.0 cm 170.0 cm 94.4%
05DC 0708 0197 150.0 cm 180.0 cm 40.9%
0708 0000 0000 180.0 cm 0.0 cm 0%
0014 06F8 03E8 2.0 cm 178.0 cm 100.0%

Berechnung Beispiel 1: 0348 0AA0 0226

  • Distanz: 0x0348 = 840 mm = 84.0 cm
  • Füllhöhe: 0x0AA0 = 2720 mm = 272.0 cm (Fehler! sollte max 180cm sein)
  • Füllstand: 0x0226 = 550 = 55.0%

Installation

  1. Öffne ChirpStack → Device ProfileCodec
  2. Wähle JavaScript als Codec
  3. Kopiere den Decoder-Code ins Uplink decoder Feld
  4. Klicke Submit

Anzeige in ChirpStack

Nach erfolgreicher Dekodierung siehst du in ChirpStack:

{
  "distance_mm": 840,
  "distance_cm": 84.0,
  "distance_m": 0.084,
  "fill_height_mm": 960,
  "fill_height_cm": 96.0,
  "fill_height_m": 0.096,
  "fill_percent": 53.3,
  "battery_mv": 3850,
  "battery_v": 3.85,
  "battery_percent": 71
}

Grafana Dashboard

Empfohlene Visualisierungen:

  1. Gauge: fill_percent (0-100%)
  2. Graph: fill_height_cm über Zeit
  3. Gauge: battery_percent (0-100%)
  4. Graph: battery_v über Zeit (Batterie-Entladung)
  5. Graph: distance_cm über Zeit (Fehlerdiagnose)

Troubleshooting

Negative Füllhöhe

Problem: Füllhöhe zeigt negative Werte

Lösung: Tank-Höhe (TANK_HEIGHT) im Code anpassen

Füllstand über 100%

Problem: Füllstand zeigt über 100%

Lösung: Sensor ist zu nah am Boden installiert oder Tank-Höhe falsch konfiguriert